4.0 Article

Densitometer-Specific Differences in the Correlation Between Body Mass Index and Lumbar Spine Trabecular Bone Score

期刊

JOURNAL OF CLINICAL DENSITOMETRY
卷 20, 期 2, 页码 233-238

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jocd.2016.11.003

关键词

Body mass index; bone mineral density; cohort study; densitometer; trabecular bone score

资金

  1. Canadian Institutes of Health Research (CIHR) [MOP 111103]
  2. Amgen
  3. Eli Lilly Canada

向作者/读者索取更多资源

Trabecular bone score (TBS) is a gray-level texture measure derived from lumbar spine dual-energy X-ray absorptiometry (DXA) images that predicts fractures independent of bone mineral density (BMD). Increased abdominal soft tissue in individuals with elevated body mass index (BMI) absorbs more X-rays during image acquisition for BMD measurement and must be accommodated by the TBS algorithm. We aimed to determine if the relationship between BMI and TBS varied between 2 major manufacturers' densitometers, because different densitometers accommodate soft tissues differently. We identified 1919 women and 811 men, participants of the Canadian Multicentre Osteoporosis Study, aged >= 40 yr with lumbar spine DXA scans acquired on GE Lunar (4 centers) or Hologic (3 centers) densitometers at year 10 of follow-up. TBS was calculated for L1-LA (TBS iNsight (R) software, version 2.1). A significant negative correlation between TBS and BMI was observed when TBS measurements were performed on Hologic densitometers in men (Pearson r = 0.36,p < 0.0001) and in women (Pearson r = 0.33,p < 0.0001); significant correlations were not seen when TBS was measured on GE Lunar densitometers (Pearson r = 0.00 in men, Pearson r = 0.02 in women). Age-adjusted linear regression models confirmed significant interactions between BMI and densitometer manufacturer for both men and women (p < 0.0001). In contrast, comparable positive correlations were observed between BMD and BMI on both Hologic and GE Lunar densitometers in men and women. In conclusion, BMI significantly affects TBS values in men and women when measured on Hologic but not GE Lunar densitometers. This finding has implications for clinical and research applications of TBS, especially when TBS is measured sequentially on DXA densitometers from different manufacturers or when results from different machines are pooled for analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据