4.6 Article

Development and application of a new in-line coupling of a miniaturized boronate affinity monolithic column with capillary zone electrophoresis for the selective enrichment and analysis of cis-diol-containing compounds

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1494, 期 -, 页码 65-76

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2017.03.014

关键词

Boronate affinity chromatography; Silica monolith; Capillary electrophoresis; In-line coupling; Urine; Catecholamines

向作者/读者索取更多资源

An integrated, miniaturized and fully automated system was developed for the analysis (preconcentration/purification, separation and detection) of cis-diol containing molecules in complex matrices. This innovative in-line coupling system was achieved via the in-situ and localized synthesis of a short segment of silica-based monolith at the inlet of a 75-mu m inner diameter fused silica capillary. The monolithic segment was locally functionalized with an acrylamide derivative of phenylboronic acid by free radical photopolymerization within 10 min of irradiation time. Efficiency of the photopolymerization reaction was followed by frontal affinity chromatography of 1,2-dihydroxybenzene (catechol) as cis-diol model solute. An active-site amount of 0.43 nmol cm(-1) (9.8 nmol mu L-1) of phenylboronic acid moieties was obtained, with a K-d value of about 290 mu M close to reported value for the phenyl boronate-catechol complex. The optimal conditions of use of the miniaturized boronate affinity monolithic column (mu BAMC) were determined and adapted to the in-line coupling with capillary electrophoresis. Catechol was specifically preconcentrated in a pH 8.5 phosphate buffer/MeOH (80120, v/v) mixture. A volume up to 20 times the monolith volume can be percolated with a quantitative recovery yield. Three catecholamines were purified, preconcentrated and in-line separated. Elution from the mu BAMC was performed with a small plug of acidic solution, allowing field amplified sample stacking of solutes within the plug before their in-line electrophoretic separation at pH 8.75. This unique in-line coupling was successfully used for the fully automated analysis of catecholamines neurotransmitters in urine samples, highlighting the purification efficiency of the mu BAMC and the potential of such a fully integrated approach. In addition to the low sample volume required (less than 2 mu L), the limits of detection (LOD) accomplished with this coupling were estimated at 9.0, 9.5 and 4.8 ng mL(-1) for dopamine, adrenaline and noradrenaline respectively, which improves the LOD of theses solutes compared to other CE methods. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据