Influence of kinematics on the wear of a total ankle replacement

期刊

JOURNAL OF BIOMECHANICS
卷 53, 期 -, 页码 105-110

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jbiomech.2017.01.001

关键词

Total ankle replacement; Wear; Gait; Biotribology; Polyethylene

资金

  1. EPSRC
  2. Corin Group PLC
  3. NIHR Leeds Musculoskeletal Biomedical Research Unit LMBRU [LEEMKBRU-2012-1 EP/L504993/1]
  4. NIHR LMBRU
  5. EPSRC Centre for Innovative Manufacturing in Medical Devices
  6. EPSRC Innovation and Knowledge Centre in Medical Technology
  7. EPSRC [EP/N00941X/1, EP/K029592/1] Funding Source: UKRI
  8. Engineering and Physical Sciences Research Council [EP/K029592/1, EP/N00941X/1, 1369326] Funding Source: researchfish

向作者/读者索取更多资源

Total ankle replacement (TAR) is an alternative to fusion, replacing the degenerated joint with a mechanical motion-preserving alternative. Minimal pre-clinical testing has been reported to date and existing wear testing standards lack definition. Ankle gait is complex, therefore the aim of this study was to investigate the effect on wear of a range of different ankle gait kinematic inputs. Five Zenith (Corin Group) TARS were tested in a modified knee simulator for twelve million cycles (Mc). Different combinations of IR rotation and AP displacement were applied every 2Mc to understand the effects of the individual kinematics. Wear was assessed gravimetrically every Mc and surface profilometry undertaken after each condition. With the initial unidirectional input with no AP displacement the wear rate measured 1.2 +/- 0.6mm(3)/Mc. The addition of 11(circle) rotation and 9 mm of AP displacement caused a statistically significant increase in the wear rate to 25.8 +/- 3.1 mm(3)/Mc. These inputs seen a significant decrease in the surface roughness at the tibial articulation. Following polishing three displacement values were tested; 0, 4 and 9 mm with no significant difference in wear rate ranging 11.8 +/- 15.2 mm(3)/Mc. TAR wear rates were shown to be highly dependent on the addition of internal/external rotation within the gait profile with multidirectional kinematics proving vital in the accurate wear testing of TARs. Prior to surface polishing wear rates were significantly higher but once in a steady state the AP displacement had no significant effect on the wear. (C) 2017 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据