4.6 Article

Customized versus Patient-Sized Cruciate-Retaining Total Knee Arthroplasty: An In Vivo Kinematics Study Using Mobile Fluoroscopy

期刊

JOURNAL OF ARTHROPLASTY
卷 32, 期 4, 页码 1344-1350

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2016.09.034

关键词

TKA; customized TKA; cruciate-retaining; posterior stabilized; kinematics; mobile fluoroscopy

资金

  1. ConforMIS

向作者/读者索取更多资源

Background: Historically, knee arthroplasties have been designed using average patient anatomy. Recent advances in imaging and manufacturing have facilitated the development of customized prostheses designed to fit the unique shape of individual patients. The purpose of this study is to determine if improving implant design through customized total knee arthroplasty (TKA) improves kinematic function. Methods: Using state-of-the-art mobile fluoroscopy, tibiofemoral kinematics were analyzed for 24 subjects with a customized individually made (CIM), cruciate-retaining TKA, and 14 subjects having an asymmetric condylar cruciate-retaining TKA. Subjects performed a weight-bearing deep knee bend and a rise from a seated position. Each patient was evaluated for weight-bearing range of motion, femorotibial translation, femorotibial axial rotation, and condylar liftoff occurrence. Results: Subjects having a CIM TKA experienced greater weight-bearing knee flexion compared with the traditional posterior cruciate-retaining (PCR) TKA design. During flexion, the CIM TKA subjects consistently exhibited more posterior femoral rollback than the traditional PCR TKA subjects. The CIM TKA was found to have statistically greater axial rotation compared with the traditional PCR TKA (P = .05). Of note, only the CIMTKA patients experienced femoral internal rotation at full extension, as exhibited in a normal knee. Compared with the traditional PCR TKA, the CIM TKAs demonstrated minimal occurrences of paradoxical sliding and reverse rotation during flexion and extension. The CIM TKA subjects showed minimal liftoff and hence better stability in earlyflexion to midflexion compared with the traditional PCR subjects. Conclusion: The CIM TKA demonstrated kinematics more similar to a normal knee. Therefore, using customized implant technology through CIM TKA designs affords benefits including more normal motion compared with a traditional PCR TKA. (C) 2016 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据