4.2 Article

A Validated HPLC Method for Simultaneous Determination of Perindopril Arginine, Amlodipine, and Indapamide: Application in Bulk and in Different Pharmaceutical Dosage Forms

期刊

JOURNAL OF AOAC INTERNATIONAL
卷 100, 期 4, 页码 992-999

出版社

AOAC INT
DOI: 10.5740/jaoacint.16-0279

关键词

-

向作者/读者索取更多资源

A simple, accurate, and precise LC method with a reversed stationary phase was developed and validated for the determination of perindopril (PER) arginine, amlodipine (AML), and indapamide (IND) alone and in binary mixtures (PER arginine is found in two dosage forms, i.e., with either AML or IND). Chromatographic separation was carried out on a BDS Hypersil (R) C-18 column (100 x 3 mm, 5 mu m). The mobile phase, consisting of 0.05 M potassium dihydrogen phosphate buffer (pH 2.6)-methanol (50 + 50, v/v), was pumped through the column whose temperature was maintained at 50 degrees C at a flow rate of 0.6 mL/min using isocratic elution, and UV detection at 215 nm was performed. Acceptable values of linearity, accuracy, and precision of the method were found over the concentration ranges of 5-80 mu g/mL PER, 2.5-80 mu g/mL AIVIL, and 0.5-20 mu g/mL IND. The proposed chromatographic method was statistically compared to that of reference methods using one-way analysis of variance. The results showed that there was no significant difference between the methods. The developed method proved reliable for use in accurate QC of the drugs in their pharmaceutical preparations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据