4.5 Article

Assessment of the quality of TROPOMI high-spatial-resolution NO2 data products in the Greater Toronto Area

期刊

ATMOSPHERIC MEASUREMENT TECHNIQUES
卷 13, 期 4, 页码 2131-2159

出版社

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/amt-13-2131-2020

关键词

-

资金

  1. Netherlands Space Office (NSO)
  2. European Space Agency (ESA)

向作者/读者索取更多资源

The TROPOspheric Monitoring Instrument (TROPOMI) aboard the Sentinel-5 Precursor satellite (launched on 13 October 2017) is a nadir-viewing spectrometer measuring reflected sunlight in the ultraviolet, visible, near-infrared, and shortwave infrared spectral ranges. The measured spectra are used to retrieve total columns of trace gases, including nitrogen dioxide (NO2). For ground validation of these satellite measurements, Pandora spectrometers, which retrieve high-quality NO2 total columns via direct-sun measurements, are widely used. In this study, Pandora NO2 measurements made at three sites located in or north of the Greater Toronto Area (GTA) are used to evaluate the TROPOMI NO2 data products, including a standard Royal Netherlands Meteorological Institute (KNMI) tropospheric and stratospheric NO2 data product and a TROPOMI research data product developed by Environment and Climate Change Canada (ECCC) using a high-resolution regional air quality forecast model (in the air mass factor calculation). It is found that these current TROPOMI tropospheric NO2 data products (standard and ECCC) met the TROPOMI design bias requirement (< 10 %). Using the statistical uncertainty estimation method, the estimated TROPOMI upper-limit precision falls below the design requirement at a rural site but above in the other two urban and suburban sites. The Pandora instruments are found to have sufficient precision (< 0.02 DU) to perform TROPOMI validation work. In addition to the traditional satellite validation method (i.e., pairing ground-based measurements with satellite measurements closest in time and space), we analyzed TROPOMI pixels located upwind and downwind from the Pandora site. This makes it possible to improve the statistics and better interpret the high-spatial-resolution measurements made by TROPOMI. By using this wind-based validation technique, the number of coincident measurements can be increased by about a factor of 5. With this larger number of coincident measurements, this work shows that both TROPOMI and Pandora instruments can reveal detailed spatial patterns (i.e., horizontal distributions) of local and transported NO2 emissions, which can be used to evaluate regional air quality changes. The TROPOMI ECCC NO2 research data product shows improved agreement with Pandora measurements compared to the TROPOMI standard tropospheric NO2 data product (e.g., lower multiplicative bias at the suburban and urban sites by about 10 %), demonstrating benefits from the high-resolution regional air quality forecast model.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据