4.7 Article

Comparison of signal intensities and elemental fractionation in 257 nm femtosecond LA-ICP-MS using He and Ar as carrier gases

期刊

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
卷 32, 期 11, 页码 2217-2225

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c7ja00190h

关键词

-

资金

  1. National Key RP Plan [2016YFE0203000]
  2. National Science Fund for Distinguished Young Scholars
  3. National Natural Science Foundation of China [41403017, 41573015]
  4. Science Fund for Distinguished Young Scholars of Hubei Province [2016CFA047]
  5. MOST Special Fund from the State Key Laboratories of Geological Processes and Mineral Resources

向作者/读者索取更多资源

Signal intensities and elemental fractionation under different ambient gas conditions (He, Ar and a premixed He-Ar mixture) were investigated using 257 nm femtosecond (fs)-LA-ICP-MS. The experiments show that the change of ablation carrier gases from argon to helium increases the sensitivities of refractory elements (e.g. rare earth elements) in NIST SRM 610 by a factor of 1.05-1.20, whereas, the signal intensities of volatile elements (e.g. Tl, Cd, Se, Sn, Te, Zn, Pb, Bi, Ge, Ga, Sb, Ag, and Cu) were increased by a factor of 1.5-3.0. The much less deposited aerosol particles around the ablation craters produced in helium when compared to argon may partly account for this phenomenon. Our results also suggest that volatile elements may be enriched in small aerosol particles produced by femtosecond laser ablation whose transport efficiencies are increased when using He instead of Ar. The calculated elemental fractionation indices (with respect to Ca) of volatile elements (B, Cu, Zn, Ga, Ge, As, Cd, Mo, Ag, Sn, Sb, Pb and Bi) rapidly increased to 1.1-1.2 with increasing the spot size from 24 mu m to 60 mu m when using helium as the carrier gas. In contrast, they remain nearly constant at spot sizes of 24-60 mu m when using argon as the carrier gas. However, the indices of volatile elements (Co, Ni, Cu, Zn, Ga, Ge, As, Ag, Cd, Sn, Sb, Pb, and Bi) are less than 1 for all the spot sizes investigated. The signal intensities of all elements obtained in the pre-mixed He-Ar mixture is similar to the sensitivities acquired in pure helium. Meanwhile, the calculated elemental fractionation indices of all elements generally remain constant and closer to 1 than those obtained in pure He or Ar at different spot sizes. The technique of using the premixed He-Ar mixture as the carrier gas has been successfully used for the determination of major and trace elements in USGS and MPI-DING glasses by using fs-LA-ICP-MS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据