4.2 Article

Evaluation of spatial and temporal water quality in the Akkaya dam watershed (Nigde, Turkey) and management implications

期刊

JOURNAL OF AFRICAN EARTH SCIENCES
卷 129, 期 -, 页码 481-491

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jafrearsci.2017.01.034

关键词

Water pollution; Water quality; Chemical oxygen demand; Protection; Watershed management; Central Turkey

资金

  1. Omer Halisdemir University Scientific Research Institute [FEB2014/17]

向作者/读者索取更多资源

The aim of this study is to investigate the water pollution in the Akkaya Dam watershed spatially and temporally and put forward management suggestions in a watershed scale. For this purpose, monthly water sampling was performed from 11 sampling stations on streams that fed the dam. According to land surveys they have a potential to inflict pollution to the dam. Thus the physical and chemical parameters (i.e. pH, dissolved oxygen, electrical conductivity, temperature, chemical oxygen demand, turbidity and suspended solids) were monitored monthly for 1-year period. Chloride, sulfate, total nitrogen, ammonium, nitrite, nitrate were monitored for a 6-month period, and the results were evaluated in accordance with the Turkish Regulation of Surface Water Quality Management. Results of the study show that the most important reasons for the- pollution in the dam are caused by domestic and industrial wastewaters, which were released to the system without being treated, or without being sufficiently treated, and also of agricultural activities. It was determined that electrical conductivity, dissolved oxygen, turbidity, chemical oxygen demand, suspended solids, nitrite, nitrate, total nitrogen, sulfate, and chloride parameters which were high at the sampling stations where domestic and industrial wastewaters discharge were present. pH and temperature demonstrate a difference at a significant level by seasons. As a result of the study, it was determined that the water was of IVth quality in terms of nitrate, chemical oxygen demand, and total nitrogen, and it was of 111rd quality water with respect to ammonium, electrical conductivity, and dissolved oxygen. It was observed that the dam outflow water was of IVth quality with respect to nitrate, chemical oxygen demand, and total nitrogen, and of IIIrd quality with respect to dissolved oxygen and electrical conductivity. It is considered that the pollution problem in the Akkaya Dam can only be resolved with prevention studies on a watershed scale. Therefore, coordination between the institutions is necessary. The preparation for the integrated water management plan of the watershed will provide a significant contribution to the solution of the water quality problem. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据