3.8 Article

A Sensitive Simultaneous Determination of Uric Acid, Norepinephrine and Indomethacin using a Cadmium Sulfide Nanoparticles/Multi-Walled Carbon Nanotubes Modified Gold Electrode

期刊

ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY
卷 12, 期 4, 页码 486-501

出版社

UNIV TEHRAN, FAC CHEMISTRY, CENTER EXCELLENCE ELECTROCHEMISTRY

关键词

Uric acid; Norepinephrine; Indomethacin; Multi-walled carbon nanotubes; Cadmium sulfide nanoparticles; Modified electrode

资金

  1. research council of Arak University [98.65]

向作者/读者索取更多资源

In this study a novel method was developed to fabricate cadmium sulfide nanoparticles/multiwalled carbon nanotubes composite modified gold electrode (CdSNPs/MWCNTS/AuE) to measure trace amounts of norepinephrine(NE), indomethacin (IND), and uric acid (UA) simultaneously. Electrochemical investigations were carried out using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamprometery (CA) methods. Using DPV method under optimum condition, the NE anodic peak current represented a linear relationship in the two concentration ranges of 0.3 to 100.0 mu M and 100.0 to 500.0 mu M. For UA, the corresponding anodic peak current showed linear ranges from 0.5 to 100.0 mu M and from 100.0 to 350.0 mu M, and IND the corresponding linear range was between 2.0 to 80.0 mu M, respectively. Detection limits have been calculated equal to 0.16 mu M for NE, 0.09 mu M for UA, and 0.46 mu M for IND, respectively. The modified electrode has been applied for the determination of NE, UA and IND in human urine and blood serum with satisfactory results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据