4.6 Article

In situ multiplex detection of serum exosomal microRNAs using an all-in-one biosensor for breast cancer diagnosis

期刊

ANALYST
卷 145, 期 9, 页码 3289-3296

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0an00393j

关键词

-

资金

  1. Project of Natural Science Foundation of China [21775036, 21675046, 21735002, 21521063, 21806186, 21874035]
  2. Research Foundation of Education Bureau of Hunan Province [18B027]
  3. Hunan Provincial Natural Science Foundation [2018JJ2033]
  4. Key Point Research and Invention Program of Hunan Province [2017DK2011]

向作者/读者索取更多资源

Herein, a simple all-in-one biosensor based on a DNA three-way junction has been constructed for in situ simultaneous detection of multiple miRNAs by competitive strand displacement. In our design, three oligonucleotides (Y1, Y2 and Y3) of a Y-type scaffold were extended at their 5 ' ends by introducing three single-stranded recognition sequences with quenchers (BHQ1, BHQ2 and BHQ2), respectively. Subsequently, three reporter sequences labeled with different fluorophores (FAM, Cy3 and Cy5) were bound to the corresponding recognition sequences to form a multicolour DNA biosensor that gives self-quenched fluorescence. The biosensor can effectively enter into exosomes and then hybridize to the complementary miRNA targets to form longer duplexes and release the reporter sequences, thus activating the readable fluorescence signals for the simultaneous detection of multiple miRNAs in exosomes. As a proof of principle, miR-21, miR-27a and miR-375 were chosen as model targets because of their high expressions in breast cancer cells (MCF-7). Fluorescence signals of MCF-7 exosomes after being treated with the biosensor exhibited positive correlations to their concentrations and the limits of detection were determined to be 0.116 mu g mL(-1), 0.125 mu g mL(-1) and 0.287 mu g mL(-1) for exosomes by detecting three exosomal miRNAs (miR-21, miR-27a and miR-375), respectively. In contrast, there were no obvious correlations between fluorescence intensities and control MCF-10A exosome concentrations. Importantly, by testing multiple exosomal miRNAs using the biosensor in clinical serum samples, breast cancer patients can be effectively differentiated from healthy donors. Consequently, the developed biosensor demonstrates high potential as a routine bioassay for the multiplex quantification of exosomal miRNAs in clinical diagnosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据