4.6 Article

An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis

期刊

JACC-CARDIOVASCULAR INTERVENTIONS
卷 10, 期 5, 页码 489-499

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2016.11.040

关键词

COMBO stent; early vascular healing response; neointimal hyperplasia; OCT

资金

  1. OrbusNeich Medical
  2. Micell Technologies
  3. Medtronic
  4. Boston Scientific
  5. St. Jude Medical
  6. Biotronik
  7. Stentys
  8. W. L. Gore
  9. Microport
  10. SinoMedical
  11. Terumo
  12. CeloNova
  13. Biosensors

向作者/读者索取更多资源

OBJECTIVES The aim of the present study was to evaluate vascular healing of the bioengineered COMBO Dual Therapy Stent compared with a cobalt-chromium (CoCr) everolimus-eluting stent (EES) as assessed by optical coherence tomography in patients with acute coronary syndromes. BACKGROUND CD34+ cells promote endothelial repair after vascular injury. The bioengineered COMBO Dual Therapy Stent combines CD34+ cell-capturing technology with abluminal sirolimus release, but more data from clinical studies evaluating the vascular response are needed. METHODS In a prospective randomized multicenter clinical trial, 60 patients with acute coronary syndromes were randomized 1: 1 to COMBO or CoCr EES implantation. The primary endpoint was the percentage of uncovered stent struts per stent. Stent assessment by optical coherence tomography was performed at baseline and at 60 days, followed by independent core laboratory analysis. RESULTS The percentage of uncovered struts per stent was higher with the COMBO than the CoCr EES at 60 days (median 14.7% vs. 7.7%; p = 0.04). However, no significant difference in uncovered stent struts was observed in the strut level-based analysis at 60 days, which also accounted for clustering (COMBO vs. CoCr EES; 13.6% vs. 6.9%; p = 0.09; generalized linear mixed models-adjusted analysis). Neointimal thickness at 60 days was lower with the COMBO compared with the CoCr EES (median 30.17 vs. 50.26 mu m; p =0.02; stent-level analysis). There were no significant differences in the frequency of major adverse cardiac events and each component of major adverse cardiac events within the study population between the 2 groups at 30, 60, 180, 360, and 540 days post-procedure. No target vessel stent thrombosis has been documented within 540 days. CONCLUSIONS The present multicenter, prospective clinical study for the first time compared the vascular response of the bioengineered COMBO Dual Therapy Stent with a CoCr EES in patients early after acute coronary syndrome by using intracoronary optical coherence tomographic analysis. The percentage of uncovered stent struts per stent was somewhat higher after COMBO versus CoCr EES implantation as detected by optical coherence tomography, associated with reduced neointimal thickness. (C) 2017 by the American College of Cardiology Foundation. Published by Elsevier. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据