4.5 Article

Experimental study of R1234yf as a drop-in replacement for R134a in a domestic refrigerator

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2017.05.003

关键词

Domestic refrigerator; R1234yf; Drop-in; Optimal charge; Thermal analysis

资金

  1. Universidad de Guanajuato

向作者/读者索取更多资源

This paper presents an experimental study for three identical domestic refrigerators using R1234yf as a drop-in replacement for R134a. An alternative methodology was proposed to estimate the optimal mass charge for R1234yf; with the use of such methodology, new evidences were sought on the thermal behavior of the refrigerator compartments as well as at the heat exchangers. Additionally, energy performance for both refrigerants was measured, and, finally, a TEWI analysis was conducted. For the type of refrigerator evaluated, results showed that R1234yf presented an average (for the 3 refrigerators) of 0.4 degrees C for the fresh food compartment, and 1.2 degrees C for the freezer, among different charges with respect to R134a. The optimal charge for R1234yf was 92.2 g, which is about 7.8% lower than the one for R134a, which represents a small increase of 4% in energy consumption in comparison to R134a. Finally, the TEWI analysis for the R1234yf was 1.07% higher than the R134a. (C) 2017 Elsevier Ltd and IIR. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据