Computational fluid dynamics based study for analyzing heat transfer and friction factor in semi-circular rib-roughened equilateral triangular duct

出版社

EMERALD GROUP PUBLISHING LTD
DOI: 10.1108/HFF-10-2015-0438

关键词

Forced convective heat transfer and friction factor; Thermo-hydraulic performance; Turbulent models

资金

  1. DST (Department of Science and Technology), India [SR/FTP/ETA-0109/2011]

向作者/读者索取更多资源

Purpose -The purpose of this computational fluid dynamics (CFD)-based study on semicircular rib-roughened equilateral triangular duct is to investigate heat transfer, friction factor and thermohydraulic performance parameter. The analysis is carried out by simulating problem in ANSYS (Fluent). The Reynolds number in the study varies from 4,000 to 24,000. Nusselt number is calculated for different Reynolds number using various turbulent models available in ANSYS (Fluent) for a smooth duct and compared the results with the Dittus-Boelter correlation. Design/methodology/approach -The analysis has been done by solving basic fluid governing equations (continuity, momentum and energy) by using finite volume method (FVM). The semicircular ribs were fabricated on the absorber plate. The constant amount of heat flux is applied on the absorber plate, whereas other two walls are made adiabatic. The semi-implicit method for pressure linked equations (SIMPLE) algorithm is used with pressure-velocity-coupled disretization to estimate the results. The selection of turbulent model has been done on the basis of Nusselt number prediction in the smooth duct. Findings -The renormalization-group k-epsilon model predicts the Nusselt number more accurately as compared to standard k-epsilon model, standard k-omega model, shear stress transport (SST) k-omega and realizable k-omega model in the Reynolds number ranges from 4,000 to 24,000 with a 6 5.5% deviation from Dittus-Boelter equation for smooth duct. Themaximum thermo-hydraulic performance is observed of the order of 1.7 for arrangement which has a relative roughness height of 0.067 and relative roughness pitch of 7.5 at higher Reynolds Number of 24,000. Originality/value -Although, many experimental studies are available in the area of rib-roughened ducts, the present study is based on CFD analysis of semicircular rib-roughened equilateral triangular duct and the results are predicted in terms of Nusselt number, friction factor and thermohydraulic performance parameter. Moreover, the predicted result of Nusselt number and friction factor is validated by comparing with Dittus-Boelter correlation and modified Blasius equation, respectively. This advantage made Fluent a powerful tool for analyzing the internal fluid flow through roughened ducts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据