4.6 Article

A smart luminescent metal-organic framework-based logic system for simultaneous analysis of copper ions and hydrogen sulfide

期刊

JOURNAL OF MATERIALS CHEMISTRY C
卷 8, 期 25, 页码 8635-8642

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0tc00698j

关键词

-

资金

  1. National Key Research and Development Program of China [2018YFC1105702, 2016YFA0203700]
  2. National Natural Science Foundation of China [51621002, 21805087]
  3. Shanghai Sailing Program [18YF1405900]
  4. China Postdoctoral Science Foundation [2017M621383]
  5. Program of Shanghai Academic/Technology Research Leader [18XD1401400]
  6. Basic Research Program of Shanghai [17JC1404702]
  7. Leading talents in Shanghai in 2018
  8. Program for Professor of Special Appointment (Eastern Scholar) at Shanghai Institutions of Higher Learning
  9. 111 project [B14018]

向作者/读者索取更多资源

Simultaneous detection of multiple targets is in imperative demand but is challenging for analysis technology. In this study, a novel, multi-input luminescent logic system based on a nanoscale Zr(iv)/Eu(iii) metal-organic framework (Zr-pydc-Eu) is designed for simultaneous identification and quantification of copper ions and hydrogen sulfide, which are considered to be not only toxic species in the environment but also associated with various physiological and pathological processes in the human body. In the MOF-based logic gate, pyridine-2,5-dicarboxylic acid (pydc) behaves as both the energy donor and the metal-chelating site, the photoactive Eu(3+)ions function as the luminescence signal reporter/output, and the target analytes (Cu(2+)and H2S) serve as energy modulators/inputs. By using the specific Cu(2+)ions as a single input among various metal ions, the NOT logic operation is realized in Zr-pydc-Eu with the output switching from 1 to 0. With the sequentially restored output from 0 to 1 by H2S input over the biologically relevant species, the IMPLICATION logic gate is implemented. Such features enable this Zr-pydc-Eu logic system to be an effective and smart platform for analyzing both Cu(2+)and H2S with a low detection limit (10(-8)M) and a real-time response (<2 min), presenting significant potentials for multiplex analysis application in human health monitoring.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据