4.6 Article

Conductive, self-healable and reusable poly(3,4-ethylenedioxythiophene)-based hydrogels for highly sensitive pressure arrays

期刊

JOURNAL OF MATERIALS CHEMISTRY C
卷 8, 期 25, 页码 8654-8667

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0tc01947j

关键词

-

资金

  1. MINECO-FEDER [RTI2018-098951-B-I00]
  2. Agencia de Gestio d'Ajuts Universitaris i de Recerca [2017SGR359, 2017SGR1165]
  3. Generalitat de Catalunya

向作者/读者索取更多资源

Although challenging, the preparation of pure conducting polymer (CP) hydrogels as conductive flexible networks for developing high-performance functional platforms is an outstanding alternative to conventional approaches, as for example those based on the cross-linking of insulating polymers with CP segments and the simple utilization of CPs as fillers of insulating hydrogel networks. In this work, we propose the employment of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) to prepare conductive hydrogels by partially replacing the PSS dopant by alginate (Alg) chains, which is energetically favoured. The capacity of Alg chains to be electrostatically cross-linked by Ca(2+)ions has allowed us to obtain hydrogels with good electrical percolation response and mechanical properties. Hydrogels were prepared in a very simple one-step process by adding CaCl(2)to different mixtures of PEDOT : PSS and alginic acid (1 : 3, 1 : 1 and 3 : 1). After structural, chemical and physical characterization, the 1 : 3 PEDOT/Alg hydrogel was moulded to fabricate stretchable touch-pressure sensor arrays, which exhibited fast response and good spatial resolution of the pressure distribution. In addition, the PEDOT/Alg hydrogel is self-healable which allowed us to prepare reusable pressure sensors (i.e.devices that can be reprocessed to be used in their original application) thanks to the reversibility of the noncovalent Ca(2+)crosslinks. Reusable devices are different to reclaimed and recycled devices as these are no longer used for the same application because the materials lose their properties. With our hydrogels we are a step closer to a circular economy by allowing the reuse of electronic devices and reducing electronic waste worldwide. Moreover, the superior performance of the PEDOT/Alg hydrogel opens up its utilization as an efficient and flexible pressure sensor for wearable human-electronic interfaces, in which reusability would be an added value.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据