Purpose: This study investigates the feasibility of non-invasively determining thermal diffusivity () and the Pennes perfusion parameter (w) from pre-clinical and clinical magnetic resonance-guided focussed ultrasound (MRgFUS) temperature data.Materials and methods: Pre-clinical MRgFUS experiments were performed in rabbit muscle (N=3, 28 sonications) using three-dimensional MR thermometry. Eight sonications were made in a clinical QA phantom with two-dimensional thermometry. Retrospective property determination was performed on clinical uterine fibroid (N=8, 9 sonications) and desmoid tumour (N=4, 7 sonications) data. The property determination method fits an analytical solution to MRgFUS temperatures in the coronal MR plane, including all temperatures acquired during heating and one cooling image. When possible, additional cooling data were acquired for property determination.Results: Rabbit and w from Heating Data (=0.164mm(2)s(-1), w=7.9kgm(-3)s(-1)) and Heating and Cooling Data (=0.146mm(2)s(-1), w=3.3kgm(-3)s(-1)) were within the range of gold-standard invasive measurements, with >50% reduction in variability by including cooling data. QA phantom property determination with cooling data yielded properties within 3% of expected values (=0.144mm(2)s(-1), w=0.0kgm(-3)s(-1)), a difference that was not statistically significant (p=0.053). Uterine fibroid (Heating Data: =0.212mm(2)s(-1), w=11.0kgm(-3)s(-1)) and desmoid tumour (Heating & Cooling Data: =0.245mm(2)s(-1), w=4.7kgm(-3)s(-1)) properties are feasible but lack independent verification.Conclusions: Thermal diffusivity and the Pennes perfusion parameter can be obtained from in vivo data and with clinical MRgFUS protocols. Property values are consistently improved by including cooling data. The utility of this property determination method will increase as clinical protocols implement improved temperature imaging.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据