4.7 Article

Identification of vulnerable lines in power grids with wind power integration based on a weighted entropy analysis method

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 42, 期 31, 页码 20269-20276

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2017.06.039

关键词

Vulnerable line assessment; Incremental power flow entropy; Entropy weight analysis method; Wind power integration

资金

  1. National Science Foundation of China [51477058]
  2. Science and Technology Plan Project of Xiamen [3502Z20153029]
  3. Promotion Program for Young and Middle-aged Teacher in Science and Technology Research of Huaqiao University [ZNQ-YX304]

向作者/读者索取更多资源

Vulnerable overhead electricity lines are a cause of serious risk to power distribution grids as damage can be the cause of large scale blackouts and cascading failures. With the integration of large scale wind power into generating capacity, both the topology structure and the distribution characteristics of power flow in distribution grid have undergone various changes that have increased line vulnerability. A novel approach to identify vulnerable lines based on the weighted entropy analysis method is proposed in this paper. In this approach, an assessment index, named the incremental power flow entropy, is first developed, which is used to describe influences caused by variation of the lines' capability of carrying power flow transfers on the vulnerability of the lines themselves at the same aggregation level. A second assessment index, named structural importance, describes the structural changes of a power grid that are caused by the integration of wind-generated electric power. The two assessment indices then are merged into one index by using the entropy weight analysis method, which can assess the vulnerability of the lines from the two aspects of power flow transmission and structural links. Vulnerability analysis under different situations, such as with and without the integration of the wind farm, and sharp fluctuations in wind speed at the wind farm, were carried out on an IEEE 39-bus system integrated with a 75 MW wind farm. Simulation results verified that the proposed assessment index not only can identify the vulnerable lines in a power grid with wind farm integration but also accurately reflected the vulnerability of the internal lines of the wind farm itself. (C) 2017 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据