4.7 Article

Effect of diffusible hydrogen content on embrittlement of P92 steel

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 42, 期 27, 页码 17328-17338

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2017.05.214

关键词

Implant test; Diffusible hydrogen; Lower critical stress; P92 steel; Hydrogen assisted cracking; Heat affected zone

向作者/读者索取更多资源

In the present investigation, varying electrode conditions (dried and contaminated) have been employed during welding of P92 steel to study the effect of diffusible hydrogen level on hydrogen-assisted cracking (HAC). Shielded metal arc welding process was employed to deposit the metal on a P92 steel plate. To evaluate HAC, the Granjon implant test with varying diffusible hydrogen content in the deposited metal was utilized. The diffusible hydrogen level was measured in the deposited metal by using the mercury method. Lower critical stress (LCS), embrittlement index (EI) and normalized critical stress ratio were evaluated from the Granjon implant test. The fracture surface morphology of fractured implant specimens has been studied by using a field emission secondary electron microscope. The P92 steel plate welded by the contaminated electrode with a high level of diffusible hydrogen was found to be more susceptible to HAC. As diffusible hydrogen content increased in the deposited metal, the LCS value and EI were observed to be decreased. (C) 2017 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据