Parameter study on the fouling characteristics of the H-type finned tube heat exchangers

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2017.04.107

关键词

Waste heat recovery; H-type finned tube; Orthogonal design; Fouling resistance; Heat transfer

资金

  1. National Key Basic Research Program of China (973 Program) [2013CB228304]

向作者/读者索取更多资源

In this paper, numerical simulations were performed for the fouling characteristics and heat transfer performance after fouling on the H-type finned tube heat exchangers, and the optimum parameters studies were also conducted according to the orthogonal array design method. Firstly, the effect of row number on the fouling results were discussed. It was found that there was a critical row number N-cr = 6, and the fouling results will reach a constant value when the row number is larger than the critical row number. Then, the orthogonal array design method was employed to design the test arrangements, and the effects of six geometric parameters and two operating conditions on the fouling results as well as heat transfer performance after fouling were investigated. The order of the effects of each factor and the optimum parameters corresponding to the least fouling and best heat transfer performance after fouling were also determined. At last, a correlation of the Nusselt number after fouling Nut with the geometric parameters and the operating conditions was obtained. The results showed that the optimum conditions we determined using the orthogonal array design method do have less fouling or have better heat transfer performance after fouling than the reference cases in the test arrangements. The correlation of Nut has good prediction accuracy, and it can be useful in the design and evaluation of heat exchanger in dusty environment. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据