4.7 Article

Assessment of body force effects in flow condensation, part II: Criteria for negating influence of gravity

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2016.07.019

关键词

Flow condensation; Annular flow; Condensation heat transfer coefficient; Gravity effects; Orientation effects

资金

  1. National Aeronautics and Space Administration (NASA) [NNX13AB01G]
  2. NASA Space Technology Research Fellowship [NNX15AP29H]

向作者/读者索取更多资源

This study concerns the development of a set of mechanistic criteria 'capable of predicting the flow conditions for which gravity independent flow condensation heat transfer can be achieved. Using FC-72 as working fluid, a control -volume based annular flow model is solved numerically to provide information regarding the magnitude of different forces acting on the liquid film and identify which forces are dominant for different flow conditions. Separating the influence of body force into two components, one parallel to flow direction and one perpendicular, conclusions drawn from the force term comparison are used to model limiting cases, which are interpreted as transition points for gravity independence. Experimental results for vertical upflow, vertical downflow, and horizontal flow condensation heat transfer coefficients are presented, and show that, for the given test section, mass velocities above 425 kg/m(2) s ensure gravity independent heat transfer. Parametric evaluation of the criteria using different assumed values of mass velocity, orientation, local acceleration, and exit quality show that the criteria obey physically verifiable trends in line with those exhibited by the experimental results. As an extension, the separated flow model is utilized to provide a more sophisticated approach to determining whether a given configuration will perform independent of gravity. Results from the model show good qualitative agreement with experimental results. Additionally, analysis of trends indicate use of the separated flow model captures physics missed by simpler approaches, demonstrating that use of the separated flow model with the gravity independence criteria constitute a powerful predictive tool for engineers concerned with ensuring gravity independent flow condensation heat transfer performance. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据