期刊
INTERNATIONAL JOURNAL OF FATIGUE
卷 95, 期 -, 页码 236-242出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.ijfatigue.2016.11.001
关键词
Short-beam shear fatigue; Glare; Fiber metal laminate; Interlaminar shear
资金
- CONICET
Interlaminar shear stresses have an important role in behavior of fiber metal laminates (FMLs). Low inter laminar shear strength in the crack bridging mechanism of these materials is considered beneficial because produces delamination and this prevents fiber failure; although when this strength is too low excessive delamination can occur, leading to a less efficient mechanism. This strength also has important roles in fatigue crack nucleation of internal laminae and in cases where the material is subject to shear stresses. This paper studied quasi-static and fatigue (R= 0.1; 5 Hz) interlaminar shear behavior of a commercial FML (Glare 1 3/2) employing the short-beam shear (SBS) test in longitudinal and transversal orientations. Failure modes and the limitations of the SBS test to characterize the interlaminar shear fatigue behavior are described and discussed. (C) 2016 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据