4.5 Article

A compact incoherent broadband cavity-enhanced absorption spectrometer for trace detection of nitrogen oxides, iodine oxide and glyoxal at levels below parts per billion for field applications

期刊

ATMOSPHERIC MEASUREMENT TECHNIQUES
卷 13, 期 8, 页码 4317-4331

出版社

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/amt-13-4317-2020

关键词

-

资金

  1. PARCS project (Pollution in the Arctic System, a project of the CNRS French Arctic Initiative)
  2. Labex OSUG@2020 (Investissements d'avenir) [ANR10 LABX56]
  3. French national programme LEFE (Les Enveloppes Fluides et l'Environnement)
  4. Agence Nationale de la Recherche (ANR) [ANR-16-CE01-0011-01 EAIIST]
  5. BNP Paribas Foundation through its Climate & Biodiversity Initiative
  6. French Polar Institute (IPEV) [1177, 1169]

向作者/读者索取更多资源

We present a compact, affordable and robust instrument based on incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) for simultaneous detection of NOx, IO, CHOCHO and O-3 in the 400-475 nm wavelength region. The instrument relies on the injection of a high-power LED source in a high-finesse cavity (F similar to 33100), with the transmission signal being detected by a compact spectrometer based on a high-order diffraction grating and a charge-coupled device (CCD) camera. A minimum detectable absorption of 2.0 x 10(-10) cm(-1) was achieved within similar to 22 min of total acquisition, corresponding to a figure of merit of 1.8 x 10(-10) cm(-1) Hz(-1/2) per spectral element. Due to the multiplexing broadband feature of the setup, multi-species detection can be performed with simultaneous detection of NO2, IO, CHOCHO and O-3 achieving detection limits of 11, 0.3, 10 ppt (parts per trillion) and 47 ppb (parts per billion) (1 sigma) within 22 min of measurement, respectively (half of the time is spent on the acquisition of the reference spectrum in the absence of the absorber, and the other half is spent on the absorption spectrum). The implementation on the inlet gas line of a compact ozone generator based on electrolysis of water allows for the measurement of NOx (NO + NO2) and therefore an indirect detection of NO with detection limits for NOx and NO of 10 and 21 ppt (1 sigma), respectively. The device has been designed to fit in a 19 in., 3U (5.25 in.) rack-mount case; weighs 15 kg; and has a total electrical power consumption of < 300 W. The instrument can be employed to address different scientific objectives such as better constraining the oxidative capacity of the atmosphere, studying the chemistry of highly reactive species in atmospheric chambers as well as in the field and looking at the sources of glyoxal in the marine boundary layer to study possible implications on the formation of secondary aerosol particles.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据