4.7 Article

A fiber Bragg gratings pair embedded in a polyurethane diaphragm: Towards a temperature-insensitive pressure sensor

期刊

OPTICS AND LASER TECHNOLOGY
卷 131, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.optlastec.2020.106440

关键词

Fiber Bragg gratings; Pressure sensors; Material analysis; Temperature cross-sensitivity

资金

  1. LabPetro [0050.0022844.06.4]
  2. FAPES [85426300, 84336650]
  3. CNPq [304049/2019-0]
  4. Petrobras [2017/00702-6]
  5. Fundacao para a Ciencia e a Tecnologia (FCT) [CEECIND/00034/2018]
  6. FCT/MEC [UIDB/50025/2020, UIDP/50025/2020]
  7. national funds (OE), through FCT, I.P. [4, 5, 6, Law 57/2016]

向作者/读者索取更多资源

We report the development of a temperature-insensitive pressure sensor based on a pair of fiber Bragg gratings (FBGs) embedded in a polyurethane diaphragm. The pressure is transversely applied, causing a bending on the diaphragm. In such condition, the FBGs are positioned in opposite directions considering the diaphragm bending's neutral line as a reference. Thus, when the pressure is applied on the diaphragm, the wavelength shift occurs in opposite directions, i.e., one FBG has a blue shift and the other, red shift. The wavelength shift difference between both FBGs is analyzed, leading to a system with higher sensitivity when compared with the individual responses of each FBG. In addition, if the temperature sensitivities of each FBG are compensated, there is no difference in the wavelength shift (considering the difference between both FBGs) when the system is subjected only to temperature variations. However, if the system suffers simultaneous variation of temperature and pressure, there is a variation in the pressure sensitivity due to changes in the elastic modulus of the diaphragm caused by the temperature variations. For this reason, a compensation approach is proposed using the wavelength shift of each FBG as well as their difference. The sensor was tested for temperature, pressure and moisture absorption, where the maximum wavelength shift for the moisture absorption was 4 pm. For temperature and pressure responses, the sensor presented high sensitivity and linearity for all analyzed cases, leading to a pressure resolution of 1.75 Pa for constant temperature conditions. In pressure cycles under different temperatures, the compensation technique showed the feasibility of applying the proposed sensor in practical applications, where temperature variations as high as 30 degrees C were tested. The sensor presented a temperature cross-sensitivity of 0.33 Pa/degrees C.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据