4.5 Article

A Real-life Population Pharmacokinetic Study Reveals Factors Associated with Clearance and Immunogenicity of Infliximab in Inflammatory Bowel Disease

期刊

INFLAMMATORY BOWEL DISEASES
卷 23, 期 4, 页码 650-660

出版社

OXFORD UNIV PRESS INC
DOI: 10.1097/MIB.0000000000001043

关键词

pharmacokinetics; infliximab; inflammatory bowel disease; anti-TNF

资金

  1. Takeda
  2. MSD
  3. AbbVie
  4. Merck Sharp Dohme
  5. Ferring Pharmaceuticals
  6. Crucell
  7. Janssen Prevention Center
  8. Tillotts
  9. Ferring
  10. Jansen Biologics
  11. Merck Sharp Dome
  12. Mundipharma
  13. Norgine
  14. Shire
  15. UCB
  16. Vifor

向作者/读者索取更多资源

Background: Several factors influencing the pharmacokinetics of infliximab (IFX) in inflammatory bowel disease (IBD) have been identified. We studied the impact of patient, disease, and treatment characteristics on clearance and immunogenicity of IFX in a real-world patient-with-IBD cohort. Methods: Serum concentrations of IFX and antibodies to IFX (ATIs) were measured in patients with IBD at a single center using an enzyme-linked immunosorbent assay and radioimmunoassay. Patient, disease, and treatment characteristics were retrospectively collected along with laboratory values. Pharmacokinetics and ATI titer were analyzed simultaneously by nonlinear mixed-effects modeling. Results: Nine hundred ninety-seven IFX concentrations and 756 ATI measurements from 332 patients with IBD (253 Crohn's disease and 79 ulcerative colitis) were included. Mean (SD) IFX dose was 5.47 +/- 1.33 mg/kg. ATIs were detected in 75/332 (23%) patients; insufficient exposure below an IFX trough level of 3 mg/mL was the most predictive factor of developing ATI and resulted in a 4-fold increased risk of ATI development. ATI titer was a better predictor of IFX clearance than ATI as a dichotomous parameter. ATI titers >30 AU/mL were consistently associated with undetectable IFX concentrations. IFX clearance was affected by body weight (40-149 kg) ranging from 0.27 to 0.53 L/d, serum albumin (2-5.4 g/dL) from 0.93 to 0.24 L/d, and titers of ATIs (0-53,000 AU/mL) from 0.36 L/d to 15.93 L/d (P < 0.001). Previously biologic-treated patients exhibited a higher clearance of IFX. Conclusions: IFX exposure below 3 mg/mL increases risk of ATIs. Identification of influential pharmacokinetics and ATI factors improves prediction of IFX levels, potentially allowing individualized dosing and cost reduction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据