During heat waves, fatal overexposure to heat most often occurs at home. It is not known how factors such as building size, floor level, and different types of air conditioning (AC) contribute to excess indoor heat. We monitored indoor temperature and humidity in 36 apartments in New York City during summers 2014 and 2015 and used these values to calculate the indoor heat index (HI). We investigated the role of AC type and building-level factors on indoor HI using multilevel regression models. Thirty-four of 36 homes had AC. Central and ductless AC types were associated with the coolest indoor conditions; homes with window and portable AC were significantly warmer. Apartments on the top floor of a building were significantly hotter during heat advisory periods than other apartments regardless of the presence of AC. High indoor HI levels persisted in some homes for approximately 1 day following the end of the two heat advisory periods. We provide concrete evidence of higher heat levels in top floor apartments and in homes with certain types of AC. High heat levels that persist indoors after outdoor heat has subsided may present an underappreciated public health risk.