4.4 Article

Coordinated state-estimation method for air-conditioning loads to provide primary frequency regulation service

期刊

IET GENERATION TRANSMISSION & DISTRIBUTION
卷 11, 期 13, 页码 3381-3388

出版社

INST ENGINEERING TECHNOLOGY-IET
DOI: 10.1049/iet-gtd.2017.0176

关键词

air conditioning; frequency control; renewable energy sources; building management systems; centralised control; frequency response; power system state estimation; coordinated state-estimation method; air conditioning loads; primary frequency regulation service; large-scale renewable generation penetration; building thermal capacity; linear power- frequency characteristics; AC; bandwidth limitations; real-time centralised control method; two-level coordinated state-estimation method; coordination burden reduction; local controller; central coordinator; thermal parameters; frequency response; heterogeneous parameters; rebound effect

资金

  1. Key Technologies Research and Development Program of China [2015BAA01B01]
  2. National Science Foundation of China [51477083]

向作者/读者索取更多资源

The penetration of large-scale renewable generation leads to a shortage of primary frequency regulation resources as well as increasing regulation demand. By exploiting the thermal capacity of buildings, the authors achieve linear power-frequency characteristics comparable to turbine droop control via clustering a number of air-conditioning units (ACs) to participate in primary frequency regulation without affecting indoor comfort. Due to the bandwidth limitations and latency in communication, the real-time centralised control method face great challenges. This study proposes a two-level coordinated state-estimation method to reduce the coordination burden, in which a central coordinator and local controller for each AC are involved. The central coordinator periodically gathers the working state of every AC and estimated thermal parameters individually, then broadcasts this identified model parameters - the coordination information - to each local controller. Resorting to a state-estimation method considering the coordinated information and local measurements, local controller determines whether to toggle the state of local AC to realise a fast frequency response. Simulation results show that the approach can effectively manage a large number of ACs with heterogeneous parameters to provide a primary frequency regulation service without inducing a rebound effect.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据