期刊
SEPARATION AND PURIFICATION TECHNOLOGY
卷 251, 期 -, 页码 -出版社
ELSEVIER
DOI: 10.1016/j.seppur.2020.117393
关键词
Vapor recompressed heat pump; Energy saving performance; COP; Delta H-0; Q(R)
资金
- Postgraduate Research & Practice Innovation Program of Jiangsu province
In the paper, a systematic method is designed to decide the optimal vapor recompressed heat pump assisted distillation (VRC) scheme by comparing the heat contributed by overhead vapor (Delta H-0) and the heat required of reboiler (QR). And the influence of working fluid on VRC distillation process is considered. If the working fluid is dry fluid, the overhead stream should be preheated prior to being compressed. Three cases are selected to prove the proposed method. When the Delta H-0 is less than the Q(R), adding preheater at the top of column or auxiliary bottom reboiler are favorable choices aspects of cost (TAC), energy saving performance (TUC) and coefficient of performance of compressor (COP). When the Delta H-0 is more than Q(R), the VRC distillation process with the splitting overhead stream is the better scheme aspects of TAC, TUC and COP.