4.6 Article

Cryogen-free comprehensive heartcut multidimensional gas chromatography using a Deans switch for improved analysis of petrochemical products derived from palmitic acid oxidation

期刊

ANALYTICAL METHODS
卷 12, 期 43, 页码 5160-5167

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0ay01527j

关键词

-

资金

  1. Chulalongkorn University's Ratchadapisek Sompot Fund [DNS_62_025_23_003_1, RLI 2561 003 02 23]

向作者/读者索取更多资源

Comprehensive heartcut multidimensional gas chromatography was applied with example application for analysis of a sample obtained from palmitic acid oxidation in a Rancimat instrument. The system utilized a single Deans switch (DS) located between first dimensional semi-standard nonpolar (30 m) and second dimensional polar (60 m) columns. A cyclic multiple heartcut strategy consisting of 150 heartcuts with a 0.2 min window was applied offering comprehensive analysis and injection of a narrow band of compounds onto the second column without use of cryogenic trapping devices. Untargeted compound analysis of the sample prepared by solid phase micro-extraction was performed based on match between the experimental MS spectra and first dimensional retention indices with that from the NIST library. The sample contained the major compounds of 2-octanone, 1-methylcyclohexanol, 2,3,6-trimethylphenol, 3-phenylpropanol and 2-nonanone. This approach was then evaluated based on peak capacity and the number of identified compounds. Compared with one dimensional gas chromatography providing a total peak capacity of 172 and 43 identified compounds, the analysis performance was much more improved with a capacity of 5840 and 235 identified compounds by using comprehensive heartcut multidimensional gas chromatography with the total analysis time of 15.3 h. By comparison within the same set of identified compounds, the one dimensional and multidimensional approaches provided the MS match scores of 769 +/- 81 and 836 +/- 88, respectively. In addition, the nonlinear relationship between the analysis time and number of identifiable peaks was calculated according to the set of 235 compounds. This revealed that the analysis time could be shortened with the compensation of lower separation performance, where application of a 2.5 min heartcut window with the total analysis time of 1.2 h could result in the total peak capacity of 390 with 150 identifiable compounds.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据