4.4 Article

Eddy-Current Induction by a Coil Whose Axis is Perpendicular to that of a Tube

期刊

IEEE TRANSACTIONS ON MAGNETICS
卷 53, 期 7, 页码 -

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMAG.2017.2678460

关键词

Bessel function; cracks; eddy current; nondestructive evaluation; tube

资金

  1. National Science Foundation through the Industry-University Collaborative Research Consortium at the Center for Nondestructive Evaluation, Iowa State University [420-25-60]

向作者/读者索取更多资源

We have derived analytical expressions for the quasi-static time-harmonic electromagnetic field of a circular coil used to induce eddy currents in a tube or pipe, the axis of the coil being perpendicular to that of the conductor. The results are used to determine coil impedance variations with frequency and position due to induced current. The analysis is based on a derivation of the transverse electric field of a circular current filament in free space expressed as a single layer potential. Integration of the filament field yields the coil field and its impedance in the presence of a tube. We have used the theory and a numerical approximation in fitting the frequency dependence of experimental coil impedance and thereby determined accurate estimates of the electrical conductivity of an inconel tube and the coil lift-off. Finding these parameters is a preliminary step in evaluating coil interactions with flaws.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据