4.6 Article

Optimal Sizing and Techno-Economic Analysis of Hybrid Renewable Energy Systems-A Case Study of a Photovoltaic/Wind/Battery/Diesel System in Fanisau, Northern Nigeria

期刊

PROCESSES
卷 8, 期 11, 页码 -

出版社

MDPI
DOI: 10.3390/pr8111381

关键词

hybrid renewable energy systems; modeling; simulation and optimization; techno-economic analysis; replacement project; greenhouse gas emissions analysis; break-even grid extension distance; simple payback period; net present value; genetic algorithm; rural electrification; sub-Saharan Africa; Nigeria

向作者/读者索取更多资源

Hybrid Renewable Energy Systems (HRESs) have been touted as an appropriate way for supplying electricity to remote and off-grid areas in developing countries, especially in sub-Saharan Africa (SSA), where rural electrification challenges are the most pronounced. This study proposes a two-step methodology for optimizing and analyzing a stand-alone photovoltaic/wind/battery/diesel hybrid system to meet the electricity needs of Fanisua, an off-grid and remote village of northern Nigeria. In the first step, the MATLAB environment was used to run simulations and optimize the system via the genetic algorithm. Then, techno-economic and emissions analysis was carried out in the second step to compare the proposed system to the existing traditional modes of rural electrification in sub-Saharan Africa, namely, the grid-extension and diesel generator. The break-even distance parameter was adopted in the comparison with grid-extension. Besides, the hypothetical project of replacing the diesel generator by the optimal system was analyzed using the Simple Payback Period (SPP) and Net Present Value (NPV) parameters. The resulting optimal design architecture included an 89.271-kW photovoltaic array, a 100.31-W diesel generator, and 148 batteries with a total annualized cost (TAC) and cost of energy (COE) of USD 43,807 and USD 0.25/kWh, respectively. The break-even distance found was 16.2 km, while the NPV and SPP of the hypothetical project were USD 572,382 and 2.8 years, respectively. The savings in carbon dioxide (CO2) emissions of the proposed system compared to the grid extension and the diesel generator were found to be 85,401.08 kg/year and 122,062.85 kg/year, respectively. This study highlighted the role that solar PV-based HRESs could play in the sustainable electricity supply in rural areas of sub-Saharan Africa.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据