期刊
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION
卷 24, 期 4, 页码 2469-2476出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TDEI.2017.006270
关键词
Oil-paper insulation; partial discharge; electrical deterioration; surface morphology; chemical groups
Condition of insulation materials can be obtained by analyzing partial discharge (PD) characteristics since features of PD are closely related to it. In this paper, electrical deterioration caused by partial discharge of oil-paper insulation under long-term AC voltage is studied. Feature characteristics of PD, such as phase-resolved partial discharge analysis and equivalent time-frequency, were recorded during the test process. Electrical deterioration is divided into four stages: initial, develop, stagnation and erupt stage. Four stages are separated by pulse repetition rate and discharge magnitude of PD. In different deterioration stage, statistical characteristics of PD change significantly. Surface properties of pressboard in different deterioration stage were studied. Test results indicate that the depolarization of cellulose in pressboard is the main reason for development of partial discharge, and discharges occur in different position of pressboard in different deterioration stages.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据