4.8 Article

Decentralized transfer of contingency reserve: Framework and methodology

期刊

APPLIED ENERGY
卷 278, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2020.115703

关键词

Frequency control for contingency; Instantaneous conservative response; Adaptive latent response; Communication-free active response; Conservative response capacity

资金

  1. National Natural Science Foundation of China [51877134]

向作者/读者索取更多资源

The increasing penetration of renewable energy comes with decreasing system inertia and much faster frequency drop when contingency of large power loss occurs, which seriously threatens the security of power system operation. Meanwhile, the conventional contingency reserves will be of serious shortage and unable to satisfy security requirements in the future. To solve these problems, the concept of decentralized transfer of contingency reserve (DTCR) has been recently proposed to partially transfer the centralized contingency reserve from the supply side to the demand side, attempting to realize smart decentralized reserves with higher security and lower cost. To continue this work, this paper further elaborates the methods of implementing DTCR. Firstly, the framework of the DTCR system is formulated. Then, a refined load frequency control for contingencies is developed with millisecond level speed and appliance-level control accuracy. The proposed three-stage control strategy is composed of instantaneous conservative response (ICR), adaptive latent response (ALR), and optimal dynamic control (ODC). As the basis of all responses, an estimation method of the range of power imbalance and frequency nadir is given, considering communication mechanism and parameter errors. In the ICR, a communication-free active response scheme is proposed considering load priority and magnitude to achieve rapid nadir control, and the setting formula of conservative response capacity (CRC) to avoid unacceptable low frequency by reliable minimum load resources is presented for the first time, which can mitigate the adverse impact caused by mis-shedding and enhance the error tolerance. In the ALR, an online adaptive correction method is presented for key parameters to achieve accurate frequency restoration and decrease the impact of uncertainties in the sliding time window. Finally, the effectiveness of the proposed DTCR realization method is demonstrated through the simulation on a modified small-inertia IEEE 14-bus system with wind power penetration. Further tests indicate the ICR and ALR possess high security performance in the frequency control for handling contingencies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据