4.5 Article

A new solution for thermal interference of vertical U-tube ground heat exchanger for cold area in China

期刊

GEOTHERMICS
卷 65, 期 -, 页码 72-80

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.geothermics.2016.08.002

关键词

Vertical U-tube ground heat exchanger; Pipe insulation; Operation mode; Thermal interference

资金

  1. National Natural Science Foundation of China [51476049]

向作者/读者索取更多资源

This paper presents a new solution to reduce the thermal interference of vertical U-tube ground heat exchanger (UGHE): pipe insulation installed on the upward branch pipe of the U-tube. 3-dimensional numerical models of the UGHE with and without pipe insulation were developed to simulate the heat transfer process around the UGHE. The models were verified with previously published data. The effects of pipe insulation on outlet temperature, soil temperature, heat exchange rate per unit length of borehole depth and soil temperature recovery ratio were investigated. The effects of inlet velocity of heat transfer fluid (HTF) and the thermal conductivity of backfill material were also studied to fully assess the effects of the insulation. The results indicate that the average outlet temperature of HTF, soil temperature near the upward branch pipe and soil temperature recovery ratio all increased and the thermal interference can be effectively weakened when pipe insulation was installed. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据