4.6 Article

Lactate Testing in Suspected Sepsis: Trends and Predictors of Failure to Measure Levels

期刊

CRITICAL CARE MEDICINE
卷 43, 期 8, 页码 1669-1676

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0000000000001087

关键词

quality monitoring; serum lactate; severe sepsis; trend analysis

资金

  1. National Institutes of Health (NIH)
  2. Centers for Disease Control and Prevention [3U54CK00172-04S1]
  3. NIH [T32 AI007061]

向作者/读者索取更多资源

Objectives: Serum lactate monitoring is central to risk stratification and management of sepsis and is now part of a potential quality measure. We examined 11-year trends in lactate testing and predictors of failure to measure lactates in patients with severe sepsis. Design: Retrospective cohort study. Setting: Two U.S. academic hospitals. Patients: Adult patients admitted from 2003 to 2013. Interventions: Annual rates of lactate measurement were assessed in patients who had blood cultures ordered and patients with severe sepsis, as defined by concomitant International Classification of Diseases, Ninth Revision codes for infection and organ dysfunction. The approximate time of suspected sepsis was determined by the first blood culture order with concurrent antibiotic initiation. Multivariate analysis was performed to identify predictors of failure to measure lactates in severe sepsis cases in 2013. Measurements and Main Results: Among hospitalizations with blood culture orders, rates of lactate measurement increased from 11% in 2003 to 48% in 2013 (p < 0.001 for linear trend). Rates of repeat lactate measurement within 6 hours after lactate levels greater than or equal to 4.0 mmol/L increased from 23% to 69% (p < 0.001). Patients were progressively less likely to be on vasopressors at the time of first lactate measurement (49% in 2003 vs 21% in 2013; p < 0.001). Despite these trends, lactates were measured at the time of suspected sepsis in only 65% of patients with severe sepsis in 2013. On multivariate analysis, hospital-onset sepsis and hospitalization on a nonmedical service were significant predictors of failure to measure lactates (adjusted odds ratio, 7.56; 95% CI, 6.31-9.06 and adjusted odds ratio, 2.08; 95% CI, 1.76-2.24, respectively). Conclusions: Lactate testing has increased dramatically over time and is being extended to patients without overt shock. However, rates of serial lactate testing are still suboptimal, and lactates are not being measured in many patients with severe sepsis. Hospital-onset sepsis and nonmedical units may be high-yield targets for quality improvement initiatives.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据