4.2 Article

Novel Ultrafast Spiral Head MR Angiography Compared to Standard MR and CT Angiography

期刊

JOURNAL OF NEUROIMAGING
卷 31, 期 1, 页码 45-56

出版社

WILEY
DOI: 10.1111/jon.12791

关键词

Aneurysm; cerebral arteries; magnetic resonance angiography; parallel imaging; stroke

资金

  1. Department of Neuroradiology
  2. Projekt DEAL

向作者/读者索取更多资源

This study compared the image and diagnostic quality of TOF-Spiral-short, TOF-CS, and CTA in intracranial vessel imaging, finding that TOF-Spiral-short improved delineation of small vessels compared to CTA, with slightly reduced image quality at the skull base. TOF-Spiral-short enabled the correct identification of all vessel pathologies.
BACKGROUND AND PURPOSE Intracranial vessel imaging by time-of-flight MR angiography (TOF-MRA) is one of the most frequently performed investigations in clinical neuroradiology. Particularly in the acute setting, fast imaging is needed for diagnostics, with a sequence ideally depicting even small vessels. The purpose of this study was to compare image and diagnostic quality of a novel ultrashort TOF-MRA sequence accelerated by spiral imaging (TOF-Spiral-short) to a standard TOF-MRA sequence accelerated by compressed sensing (TOF-CS) and to CT angiography (CTA). METHODS Forty-one patients (36.6% showing vessel pathologies) who had undergone TOF-CS (acquisition duration: 4 minutes 8 seconds), TOF-Spiral-short (acquisition duration: 51 seconds; spiral imaging [accelerating factor 1.3], decreased field of view [accelerating factor 1.2], and increased voxel size [accelerating factor 3.3]), and CTA were retrospectively evaluated. Assessment of image quality, diagnostic confidence, and quantification of stenosis or aneurysm diameter were performed by two readers. RESULTS Image quality at the skull base was slightly reduced with TOF-Spiral-short compared to CTA and TOF-CS (P < .05). Delineation of small intracranial vessels was improved by TOF-Spiral-short compared to CTA (P < .0001). In TOF-Spiral-short, diagnostic confidence was not reduced compared to TOF-CS in patients with vessel pathologies. We observed no significant difference in quantitative pathology assessment between TOF-Spiral-short and the other two modalities. TOF-Spiral-short enabled the correct identification of all vessel pathologies. CONCLUSIONS Accelerating TOF-MRA of brain-feeding arteries by a novel ultrashort spiral imaging sequence shows adequate image quality and sufficient diagnostic performance. Thus, TOF-Spiral-short holds potential for fast and reliable diagnostics of vessel pathologies, particularly in the acute setting.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据