4.4 Article

The combined effects of filling ratio and inclination angle on thermal performance of a closed loop pulsating heat pipe

期刊

HEAT AND MASS TRANSFER
卷 57, 期 5, 页码 751-763

出版社

SPRINGER
DOI: 10.1007/s00231-020-02988-6

关键词

-

资金

  1. Scientific and Technological Research Council of Turkey (TUBITAK) [217 M341]

向作者/读者索取更多资源

The study demonstrates that filling ratio plays a crucial role in the thermal performance of a copper pulsating heat pipe. In vertical bottom heating mode, thermal resistance increases with increasing filling ratio, except for the lowest and topmost filling ratios of 10% and 85%. The optimum thermal performance is achieved with a filling ratio of 40% in the given conditions.
In the present study, a series of experiments are conducted to investigate the thermal performance of a copper made pulsating heat pipe consisting of uniform flow passages with the cross section of 2 mm x 2 mm. Test conditions cover two orientations (0 degrees and 90 degrees) and six different filling ratios (10%, 25%, 40%, 55%, 70% and 85%). The working fluid used in the experiments is methanol. Heat inputs are applied by 7 W intervals up to an upper safe temperature limit (mean evaporator temperature of nearly 110 degrees C). In addition to temperature measurements and relevant thermal resistance values, the flow behavior is analyzed via high speed video images. It is concluded that at vertical bottom heating mode (90 degrees), the filling ratio plays a key role in the results, and thus, obvious differences occur in thermal performance depending on the filling ratio. As a general trend, at vertical position, thermal resistance increases with increasing filling ratio for a given heat input value. As an exception, the lowest filling ratio (10%) significantly disobeys this generalization. Thus, the worst thermal performances are obtained for the lowest and topmost filling ratio values (10% and 85%). Nearly for every filling ratio, the system can operate at vertical position, while the system cannot start up and/or properly operate at horizontal position (0 degrees). When the heat pipe is placed horizontally, the effect of filling ratio on the thermal behavior significantly diminishes. As an overall evaluation (including flow patterns and evaporator temperature), the optimum thermal performance is obtained for the filling ratio of 40% in existing conditions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据