4.5 Article

A Study of the Effect of Conventional Drilling and Helical Milling in Surface Quality in Titanium Ti-6Al-4V and Ti-6AL-7Nb Alloys for Medical Applications

期刊

ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING
卷 46, 期 3, 页码 2361-2369

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s13369-020-05047-8

关键词

Helical milling; Drilling; Titanium alloys; Medical devices; Ti-6Al-4V; Ti-6Al-7Nb

资金

  1. Foundation for Science and Technology (FCT), POCI, Portugal [031556-FCT/SAICT/2017, UID/EMS/00481/2013]
  2. Fundação para a Ciência e a Tecnologia [UID/EMS/00481/2013] Funding Source: FCT

向作者/读者索取更多资源

This study analyzed the surface parameters of holes made in titanium alloys for medical devices using different manufacturing methods, finding that helical milling (HM) performed better than conventional drilling (CD) under lower feed rates and vertical step values. The Ti-6Al-7Nb alloy showed better roughness results compared to Ti-6Al-4V, making it a suitable material for medical devices.
In the manufacturing of a medical device may occur the need to make a hole with a specific function. Among current methods, conventional drilling (CD) referred in this work as drilling (D) and helical milling (HM) are two options with different potential. When making the hole, it is important to choose the most suitable method to obtain the desired geometry and ensure the functionality of the device. This work aims to analyze surface parameters such as arithmetic average height (R-a), the maximum height of the profile (R-t), the average peak to valley height (RzDIN), chip formation and the geometric deviation of holes obtained by the previously referred manufacturing processes. The specimens, with cylindrical geometry, were made of titanium alloys, Ti-6Al-4V and Ti-6Al-7Nb, currently used in the manufacture of medical devices. For this purpose, holes were made in a machining center with different feed rates (F) for both methods and in the value of vertical step (a(p)) in HM. The results obtained demonstrate that at lower F and a(p), HM presents better results. The Ti-6Al-7Nb alloy presents better roughness results compared to Ti-6Al-4V, validating it as a material able to be used in medical devices according to the fact that a lower roughness is associated with higher corrosion resistance and fewer fatigue problems derived from it in components. By the work carried out, it can be concluded that the roughness values obtained in HM are lower than those obtained by D making HM as a better option in hole making.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据