Intradialytic haemodynamic instability is a significant clinical issue in hemodialysis patients. Continuous non-invasive blood pressure monitoring using pressure sensors in the dialysis circuit could provide a feasible solution, without the need for direct patient contact. The study demonstrates the potential for deriving continuous brachial pressure measurements from arterial and venous line pressures, offering a promising approach for developing a practical continuous blood pressure monitoring device.
Objective: Intradialytic haemodynamic instability is a significant clinical problem, leading to end-organ ischaemia and contributing to morbidity and mortality in haemodialysis patients. Non-invasive continuous blood pressure monitoring is not currently part of routine practice but may aid detection and prevention of significant falls in blood pressure during dialysis. Brachial blood pressure is currently recorded intermittently during haemodialysis via a sphygmomanometer. Current methods of continuous non-invasive blood pressure monitoring tend to restrict movement, can be sensitive to external disturbances and patient movement, and can be uncomfortable for the wearer. Additionally, poor patient blood circulation can lead to unreliable measurements. In this feasibility study we performed an initial validation of a novel method and associated technology to continuously estimate blood pressure using pressure sensors in the extra-corporeal dialysis circuit, which does not require any direct contact with the person receiving dialysis treatment. Method: The paper describes the development of the measurement system and subsequent in vivo patient feasibility study with concurrent measurement validation by Finapres Nova physiological measurement device. Real-time physiological data is collected over the entire period of (typically 4-hour) dialysis treatment. Results: We identify a quasi-linear mathematical function to describe the relationship between arterial line pressure and brachial artery BP, which is confirmed in a patient study. The results from this observational study suggest that it is feasible to derive a continuous measurement of brachial pressure from continuous measurements of arterial and venous line pressures via an empirically based and updated mathematical model. Conclusion: The methodology presented requires no interfacing to proprietary dialysis machine systems, no sensors to be attached to the patient directly, and is robust to patient movement during treatment and also to the effects of the cyclical pressure waveforms induced by the hemodialysis peristaltic blood pump. This represents a key enabling factor to the development of a practical continuous blood pressure monitoring device for dialysis patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据