4.7 Article

Integrated microfluidic platform with electrohydrodynamic focusing and a carbon-nanotube-based field-effect transistor immunosensor for continuous, selective, and label-free quantification of bacteria

期刊

LAB ON A CHIP
卷 21, 期 1, 页码 184-195

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0lc00783h

关键词

-

资金

  1. National Research Foundation of Korea (NRF) - Korea government (Ministry of Science and ICT) [2020R1A2C1011583]
  2. ITRC (Information Technology Research Center) support program - Korea government (Ministry of Science and ICT) [IITP-2020-2017-0-01635]
  3. Basic Science Research Program through the NRF - Ministry of Education [2020R1A6A1A03040570]
  4. National Research Foundation of Korea [2020R1A2C1011583] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

An immunosensor utilizing electrohydrodynamic focusing and DEP concentration was developed for continuous and label-free detection of flowing Staphylococcus aureus. The sensor demonstrated good linearity in detecting S. aureus concentrations, with a capture time of 35 min and a limit of detection of 150 CFU mL(-1). The use of electrical manipulation and biological interaction also provided high specificity in measurements.
Electrokinetic technologies such as AC electro-osmosis (EO) and dielectrophoresis (DEP) have been used for effective manipulation of bacteria to enhance the sensitivity of an assay, and many previously reported electrokinetics-enhanced biosensors are based on stagnant fluids. An effective region for positive DEP for particle capture is usually too close to the electrode for the flowing particles to move toward the detection zone of a biosensor against the flow direction; this poses a technical challenge for electrokinetics-assisted biosensors implemented within pressure-driven flows, especially if the particles flow with high speed and if the detection zone is small. Here, we present a microfluidic single-walled carbon nanotube (SWCNT)-based field-effect transistor immunosensor with electrohydrodynamic (EHD) focusing and DEP concentration for continuous and label-free detection of flowing Staphylococcus aureus in a 0.01x phosphate buffered saline (PBS) solution. The EHD focusing involved AC EO and negative DEP to align the flowing particles along lines close to the bottom surface of a microfluidic channel for facilitating particle capture downstream at the detection zone. For feasibility, 380 nm-diameter fluorescent beads suspended in 0.001x PBS were tested, and 14.6 times more beads were observed to be concentrated in the detection area with EHD focusing. Moreover, label-free, continuous, and selective measurement of S. aureus in 0.01x PBS was demonstrated, showing good linearity between the relative changes in electrical conductance of the SWCNTs and logarithmic S. aureus concentrations, a capture/detection time of 35 min, and a limit of detection of 150 CFU mL(-1), as well as high specificity through electrical manipulation and biological interaction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据