4.4 Article

Determination of sodium and potassium contents in palm-based polyols using graphite furnace atomic absorption spectrometer

期刊

CHEMICAL PAPERS
卷 75, 期 6, 页码 2561-2574

出版社

SPRINGER INT PUBL AG
DOI: 10.1007/s11696-020-01493-8

关键词

Graphite furnace atomic absorption spectrometer; Sodium; Potassium; Palm-based polyol; Dissolution

向作者/读者索取更多资源

This study focused on the development of methods for determination of Na and K in palm-based polyols (PBP) using graphite furnace atomic absorption spectrometer (GF AAS). The results showed that the Na and K contents in the samples were within the limits allowed for polyurethane (PU) production, indicating the effectiveness of the developed GF AAS method.
In the production of palm-based polyols (PBP), multiple purification steps might introduce sodium (Na) and potassium (K) into the polyols. The Na and K have potential to influence reactivity of polyether polyols with isocyanate in polyurethane (PU) production. The Na and K contents in polyether polyols for PU production are both limited to 10 mg kg(-1). This study focuses on method(s) development for determination of Na and K in PBP by graphite furnace atomic absorption spectrometer (GF AAS) using dilution in isopropyl alcohol as a sample preparation method. All measurements were performed without any chemical modifier. In GF AAS analysis, it is essential to establish the optimum temperature program which includes pyrolysis and atomization temperature. At the optimized condition, the developed method was validated according to the validation protocol described by International Conference on Harmonization (ICH) and AOAC International. Several parameters were evaluated include linearity of calibration curve, limit of detection (LOD), limit of quantitation (LOQ), sensitivity, recovery, and precision. The optimization of temperature program for both Na and K determinations deduced the optimum pyrolysis and atomization temperature of 900 and 1600 degrees C, respectively. The method for Na determination concludes as follows: the analytical curve showed linear correlation with R-2 value of 0.9928. The LOD and LOQ were 0.307 and 1.025 mu g kg(-1), respectively. Recoveries in the range of 97 to 108% were obtained from spiked samples (4-12 mu g kg(-1)). Whereas, the method for K determination deduces as follows: the analytical curve showed linear correlation with R-2 value of 0.9985. The LOD and LOQ were 0.249 and 0.829 mu g kg(-1), respectively. Recoveries in the range of 90-109% were obtained from spiked samples (4-12 mu g kg(-1)). The Na and K contents obtained from the developed GF AAS method are in agreement with inductively coupled plasma optical emission spectrometry (ICP OES) with 95% confidence level. The Na and K contents in PBP samples were within the limit allowed for PU production.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据