4.7 Article

Mechanical power during extracorporeal membrane oxygenation and hospital mortality in patients with acute respiratory distress syndrome

期刊

CRITICAL CARE
卷 25, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s13054-020-03428-x

关键词

Mechanical power; Acute respiratory distress syndrome; Extracorporeal membrane oxygenation; Ventilator-induced lung injury; Functional lung size; Compliance; Mortality

资金

  1. Chang Gung Memorial Hospital [CORPG3G0151]

向作者/读者索取更多资源

Mechanical power (MP) is a crucial factor for ARDS patients receiving ECMO, and MP referenced to compliance is more predictive for mortality than MP alone.
BackgroundMechanical power (MP) refers to the energy delivered by a ventilator to the respiratory system per unit of time. MP referenced to predicted body weight (PBW) or respiratory system compliance have better predictive value for mortality than MP alone in acute respiratory distress syndrome (ARDS). Our objective was to assess the potential impact of consecutive changes of MP on hospital mortality among ARDS patients receiving extracorporeal membrane oxygenation (ECMO). MethodsWe performed a retrospective analysis of patients with severe ARDS receiving ECMO in a tertiary care referral center in Taiwan between May 2006 and October 2015. Serial changes of MP during ECMO were recorded.ResultsA total of 152 patients with severe ARDS rescued with ECMO were analyzed. Overall hospital mortality was 53.3%. There were no significant differences between survivors and nonsurvivors in terms of baseline values of MP or other ventilator settings. Cox regression models demonstrated that mean MP alone, MP referenced to PBW, and MP referenced to compliance during the first 3 days of ECMO were all independently associated with hospital mortality. Higher MP referenced to compliance (HR 2.289 [95% CI 1.214-4.314], p=0.010) was associated with a higher risk of death than MP itself (HR 1.060 [95% CI 1.018-1.104], p=0.005) or MP referenced to PBW (HR 1.004 [95% CI 1.002-1.007], p<0.001). The 90-day hospital mortality of patients with high MP (>14.4 J/min) during the first 3 days of ECMO was significantly higher than that of patients with low MP (14.4 J/min) (70.7% vs. 46.8%, p=0.004), and the 90-day hospital mortality of patients with high MP referenced to compliance (>0.53 J/min/ml/cm H2O) during the first 3 days of ECMO was significantly higher than that of patients with low MP referenced to compliance (0.53 J/min/ml/cm H2O) (63.6% vs. 29.7%, p<0.001).ConclusionsMP during the first 3 days of ECMO was the only ventilatory variable independently associated with 90-day hospital mortality, and MP referenced to compliance during ECMO was more predictive for mortality than was MP alone.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据