4.6 Article

A recyclable tetracycline imprinted polymeric SPR sensor: in synergy with itaconic acid and methacrylic acid

期刊

NEW JOURNAL OF CHEMISTRY
卷 45, 期 6, 页码 3102-3111

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0nj05364c

关键词

-

资金

  1. National Natural Science Foundation of China [20771015]
  2. National 111 Project of China's Higher Education [B07012]

向作者/读者索取更多资源

A novel tetracycline imprinted polymer sensor chip was prepared using dual functional group monomers in visible light, demonstrating high adsorption capacity and selectivity with low limits of detection and quantification. Real sample analysis showed satisfactory outcomes regarding matrix effects.
A novel tetracycline (TC) imprinted polymer was prepared in visible light via synergy of dual functional group monomers methacrylic acid (MAA) and itaconic acid (IA) for the selective detection of TC in urine and milk samples. Surface plasmon resonance (SPR) and the reversible addition fragmentation chain transfer (RAFT) mechanism were employed in combination with 4-cyano-4-[(dodecylsulfanylthiocarbonyl)sulfanyl]pentanoic acid (CDTPA) in the presence of ethylene glycol dimethacrylate (EGDMA) as the cross-linker. In addition, the ratio of template, IA, MAA and EGDMA was optimized (0.8 : 0.3 : 5 : 9) by real time monitoring via SPR. The surface of the TC imprinted sensor chip was characterized by contact angle measurements, Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscopy (SEM). The (IA-MAA@SPR)MIP sensor chip displayed a high adsorption capacity and selectivity in comparison to other analogues and non-imprinted polymer (NIP) based sensor chips. Through 7 adsorption-desorption cycles, the (IA-MAA@SPR)MIP sensor chip exhibited a good recoverability. These features suggested that the IA-MAA based sensor chip was an ideal candidate for the detection of TC. Consequently, within the concentration range of 1 x 10(-13)-1 x 10(-7) mol L-1, the reflectivity changes versus the negative logarithm of concentrations presented excellent linearity; R-2 = 0.99. Based on a linear equation, the IA-MAA@SPR MIP sensor chip showed lower values for the limit of detection (LOD) and limit of quantification (LOQ) i.e. 1.38 x 10(-14) mol L-1 and 4.5 x 10(-14) mol L-1, respectively. Furthermore, the influence of the matrix on the sensor chip was successfully analyzed in real samples with satisfactory outcomes. Hence, IA-MAA based MIPs in combination with the SPR sensor chip demonstrated potential application prospects for rapid and effective sensing even in the complicated matrices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据