4.6 Article

High temperature (nano)thermometers based on LiLuF4:Er3+,Yb3+ nano- and microcrystals. Confounded results for core-shell nanocrystals

期刊

JOURNAL OF MATERIALS CHEMISTRY C
卷 9, 期 10, 页码 3589-3600

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d0tc05865c

关键词

-

资金

  1. Ghent University [BOF/STA/202002/004]
  2. FWO-Vlaanderen
  3. European Union Horizon 2020 FET-Open project NanoTBTech [801305]

向作者/读者索取更多资源

This study investigates the application of lanthanide-doped nanoparticles at high temperatures, revealing the influence of core-shell structures on thermometric properties and the presence of additional thermal coupling at elevated temperatures. Strategies for increasing relative sensitivity and maintaining high temperature precision at higher temperatures are proposed.
Recent technological developments require knowledge of temperature down to the micro- or even nano-scale. Lanthanide-doped nanoparticles became a popular tool to achieve this. Their temperature sensitive luminescence enables their application as remote thermometers and for mapping temperature profiles with high spatial resolution. Applicability of luminescence thermometry is, however, often limited at high temperatures. In nanoelectronics or chemical reactors, high temperatures above 500 K are common and new approaches for accurate high temperature sensing need to be developed. In this work, we report three different shapes of upconverting LiLuF4:2% Er3+,18% Yb3+ nanocrystals both with and without shells and study the influence of the shell on the thermometric properties. We observed peculiar behavior of the core-shell particles suggesting the presence of the dopants within the protective and 'undoped' shells. Coating the nanoparticles with a silica layer extends the operational temperature range. In an upconversion (UC) Yb3+-Er3+ system temperature sensing relies on thermal coupling between the S-4(3/2) and H-2(11/2) energy levels. At sufficiently high temperatures (>550 K), we observe additional thermal coupling involving the higher F-4(7/2) energy levels. The larger energy gap allows to increase the relative sensitivity at elevated temperatures and to sustain a high temperature precision over a wider temperature range than for a two-level Boltzmann thermometer. The thermal coupling between the S-4(3/2) and H-2(11/2) energy levels is used for lower temperature sensing (<550 K) and the F-4(7/2) energy level is crucial for higher temperature sensing (>550 K).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据