期刊
INDIAN JOURNAL OF OPHTHALMOLOGY
卷 69, 期 4, 页码 982-984出版社
WOLTERS KLUWER MEDKNOW PUBLICATIONS
DOI: 10.4103/ijo.IJO_2729_20
关键词
COVID-19; dry lab; model eye; simulator; surgical training; vitreoretinal surgery
The COVID-19 pandemic has led to a decrease in patient volumes in Ophthalmology, resulting in fewer surgical training opportunities for trainee surgeons. To address this, a simple, cost-effective RetiSurge model eye was developed for training in Vitreoretinal surgery.
The COVID-19 pandemic has resulted in reduction of patient volumes in Ophthalmology. With only emergency surgical procedures being performed with few elective surgical procedures, surgical volumes are at an all-time low. This has resulted in decreased surgical training opportunities for trainee surgeons. We developed a simple, cost-effective, 3D printed model eye - RetiSurge - for Dry Lab vitreoretinal surgery training. The model incorporates a retinal film that can be changed, making it suitable for multiple uses. The RetiSurge model can be used to practice visualization, instrument manipulation and endolaser photocoagulation. RetiSurge can be sterilized by ethylene oxide and is safe for use inside the operating room. RetiSurge is a simple, cost-effective, and reusable model eye for early training in Vitreoretinal surgery.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐