4.6 Article

The parameter optimization of lasers' energy ratio of the double-pulse laser induced breakdown spectrometry for heavy metal elements in the soil

期刊

ANALYTICAL METHODS
卷 13, 期 12, 页码 1502-1510

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1ay00237f

关键词

-

资金

  1. Jilin Provincial Environmental Protection Agency of China [JIHUANKEZI:2018-18]
  2. National Natural Science Foundation of China [61505066]

向作者/读者索取更多资源

Laser-induced breakdown spectroscopy (LIBS) is widely used in heavy metal detection in soil, but faces challenges of low precision and high detection limits. Double-pulse LIBS (DP-LIBS) is a technology aimed at improving LIBS spectral intensity by adjusting the energy ratio of two lasers and finding optimal inter-pulse times for signal enhancement. This study demonstrates that DP-LIBS outperforms single-pulse LIBS, showing enhanced analytical performance for quantitative heavy metal analysis in soil.
Laser-induced breakdown spectroscopy (LIBS) is a rapid, no-sample preparation, remote detection method that has been applied widely in the area of heavy metal detection in the soil. However, the promotion of LIBS is limited by its disadvantages, such as low precision analysis, a high detection limit, and so on. In recent years, many studies have been conducted to improve the LIBS spectral intensity. The double-pulse LIBS (DP-LIBS) is a representative technology in this area. Most of the research work focuses on the analytical methods of DP-LIBS, including the spatial configuration, the inter-pulse time, and the effect of signal enhancement of the DP-LIBS. However, there are few reports about the effect of the energy proportion of the two lasers and the contribution of different laser energies on the signal enhancement, and the inter-pulse time under the conditions of different laser energies. Moreover, DP-LIBS is mostly evaluated by the enhancement factor of the spectral signal, and there are few reports on the quantitative analysis of double-pulse LIBS. This study, which mainly detects Cu, Ni, and Pb in the soil, focuses on the contribution of the signal enhancement by adjusting the energy ratio of the two lasers and the best inter-pulse time under the conditions of different laser energies. Then, quantitative analysis of spectral signals obtained by single-pulse LIBS (SP-LIBS) and DP-LIBS are performed based on the random forest (RF) model. The results demonstrate that DP-LIBS shows better analytical performance than SP-LIBS, the coefficients of determination (R-2) of the test have great improvement, the root-mean-squared error (RMSE) is much decreased and the relative error is much improved. Thus, this study shows that DP-LIBS is an effective method for the quantitative analysis of heavy metals in the soil.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据