4.7 Review

Diagnostic accuracy of the 4AT for delirium detection in older adults: systematic review and meta-analysis

期刊

AGE AND AGEING
卷 50, 期 3, 页码 733-743

出版社

OXFORD UNIV PRESS
DOI: 10.1093/ageing/afaa224

关键词

delirium; 4AT systematic review; screening tool; older patients; dementia

资金

  1. Wellcome Trust-University of Edinburgh Institutional Strategic Support Fund [IS3-T06/03]

向作者/读者索取更多资源

The 4A's Test (4AT) shows good diagnostic accuracy for delirium in older adults according to a systematic review and meta-analysis of 17 studies. These findings support its routine use in clinical practice for delirium detection.
Objective: Detection of delirium in hospitalised older adults is recommended in national and international guidelines. The 4 A's Test (4AT) is a short (<2 minutes) instrument for delirium detection that is used internationally as a standard tool in clinical practice. We performed a systematic review and meta-analysis of diagnostic test accuracy of the 4AT for delirium detection. Methods: We searched MEDLINE, EMBASE, PsycINFO, CINAHL, dinicaltrials.gov and the Cochrane Central Register of Controlled Trials, from 2011 (year of 4AT release on the website www.the4AT.com) until 21 December 2019. Inclusion criteria were: older adults (>65 years); diagnostic accuracy study of the 4AT index test when compared to delirium reference standard (standard diagnostic criteria or validated tool). Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Pooled estimates of sensitivity and specificity were generated from a bivariate random effects model. Results: Seventeen studies (3,702 observations) were included. Settings were acute medicine, surgery, a care home and the emergency department. Three studies assessed performance of the 4AT in stroke. The overall prevalence of delirium was 24.2% (95% CI 17.8-32.1%; range 10.5-61.9%). The pooled sensitivity was 0.88 (95% CI 0.80-0.93) and the pooled specificity was 0.88 (95% CI 0.82-0.92). Excluding the stroke studies, the pooled sensitivity was 0.86 (95% CI 0.77-0.92) and the pooled specificity was 0.89 (95% CI 0.83-0.93). The methodological quality of studies varied but was moderate to good overall. Conclusions: The 4AT shows good diagnostic test accuracy for delirium in the 17 available studies. These findings support its use in routine clinical practice in delirium detection.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据