4.6 Article

Electrochemical sensor based on multi-walled carbon nanotubes for imidacloprid determination

期刊

ANALYTICAL METHODS
卷 13, 期 18, 页码 2124-2136

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1ay00198a

关键词

-

资金

  1. CAPES/Funcap [2133/2012/proc. 23038.007973/2012-90, PNE-0112-00048.01.00/16]
  2. CNPq [305136/2018-6, 405596/2018-9, 302801/2014-6, 408790/2016-4]
  3. FCT/Funcap [FCT-00141-00011.01.00/18]
  4. CoordenacAo de Aperfeicoamento de Pessoal de Nivel Superior -Brasil (CAPES) [001]
  5. FEDER funds through COMPETE
  6. FundacAo para a Ciencia e Tecnologia [UID/QUI/50006/2020, PTDC/ASP-PES/29547/2017]
  7. Norte Portugal Regional Operational Programme (NORTE 2020), under the PORTUGAL 2020 Partnership Agreement, through the European Regional Development Fund (ERDF) [Norte-01-0145-FEDER-000011, Norte-01-0145-FEDER-000024]
  8. Central Analitica-UFC/CT-INFRA/MCTI-SISNANO/Pro-Equipamentos CAPES
  9. Fundação para a Ciência e a Tecnologia [PTDC/ASP-PES/29547/2017] Funding Source: FCT

向作者/读者索取更多资源

A simple and robust sensor was developed for the determination of the widely used neonicotinoid imidacloprid (IMI) using a glassy carbon electrode modified with functionalized multi-walled carbon nanotubes (fMWCNT) and Nafion (R). The sensor showed good sensitivity and selectivity for IMI detection in complex samples.
A simple and robust sensor (fMWCNT-Nafion (R)(0.5%)/GCE) for determination of imidacloprid (IMI), a widely used neonicotinoid, was developed using a glassy carbon electrode (GCE) modified with functionalized multi-walled carbon nanotubes (fMWCNT) and Nafion (R). The obtained data suggest that IMI reduction is an irreversible process, due to the reduction of the nitro group to hydroxylamine derivatives, with the participation of two protons and four electrons, and a charge transfer coefficient of 0.141. The optimized square-wave voltammetric conditions were: McIlvaine buffer at pH 6.0, 0.5% of Nafion (R) in the fMWCNT suspension, -0.6 V and 180 s as accumulation potential and time, respectively. A linearity in the range of 2.00 x 10(-7) to 1.77 x 10(-6) mol L-1 IMI, with the values of limit of detection and limit of quantification were equal to 3.74 x 10(-8) mol L-1 and 1.25 x 10(-7) mol L-1, respectively. Repeatability and reproducibility displayed relative standard deviations lower than 5%. Recovery tests performed in tap water, melon, and shrimp yielded mean values of 94 +/- 6%, 97 +/- 10% and 93 +/- 10%, respectively. Moreover, several inorganic and organic compounds did not significantly interfere (0.6 to 4.5%) on the IMI signal, proving the selectivity and applicability of the developed sensor for IMI detection in complex samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据