4.7 Article

Parameter optimization of the spectral emission of laser-induced tungsten plasma for tokamak wall diagnosis at different pressures

期刊

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
卷 36, 期 6, 页码 1159-1169

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1ja00009h

关键词

-

资金

  1. National Key R&D Program of China [2017YFE0301304, 2017YFA0402502]
  2. National MCF Energy R&D Program of China [2019YFE03080100]
  3. National Science Foundation of China [12005034]
  4. China Postdoctoral Science Foundation [2019M660285]
  5. Kaifang project of DUT [KF2003]
  6. Fundamental Research Funds for the Central Universities [DUT19LK07]

向作者/读者索取更多资源

Gas pressure has a significant impact on plasma plume expansion and spectral emission, with 10-100 Pa pressure and 200-500 ns delay time being the optimal conditions for LIBS application in tokamak wall material diagnosis.
Laser-induced breakdown spectroscopy (LIBS) is a promising method for the in situ online diagnosis of plasma-wall interaction processes in tokamaks. The effect of gas pressure on the plume expansion and spectral emission of nanosecond laser-induced plasma of the tungsten wall material was systematically investigated using a coaxial optical configuration. A nanosecond pulsed laser (5 ns, 1064 nm) was used to ablate a tungsten target surface to produce plasma at various air pressure levels from 10(-3) Pa to 10(5) Pa. It was found that the plasma size was strongly dependent on the ambient gas pressure, and the plume presented complex behaviors such as free expansion, splitting, sharpening, confinement, etc. The spectral intensity, the signal to background ratio, and signal to noise ratio were also affected significantly by the ambient pressure. The ambient pressure influence on the plasma plume expansion and spectral emission can be ignored when the gas pressure is lower than similar to 1 Pa. The pressure of 10-100 Pa and delay time of 200-500 ns were the optimum conditions for the LIBS application in tungsten impurity of tokamak wall diagnosis. Moreover, the ablation-depth results indicated that the depth-resolution of fusion-related material analysis can be controlled by the ambient gas pressure. Temporally-resolved emission measurements were carried out to further investigate the continuum radiation and ionic and atomic emission behaviors. The temporal evolution of the electron density and electron temperature at different pressures was also determined. The plasma parameter change and laser ablation depth reduction were observed which are attributed to the ambient gas confinement and enhanced plasma shielding.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据