4.7 Article

MeV-scale performance of water-based and pure liquid scintillator detectors

期刊

PHYSICAL REVIEW D
卷 103, 期 5, 页码 -

出版社

AMER PHYSICAL SOC
DOI: 10.1103/PhysRevD.103.052004

关键词

-

资金

  1. U.S. Department of Energy, Office of Science, Office of High Energy Physics [DE-SC0018974]
  2. U.S. Department of Energy [DE-AC02-05CH11231, DE-AC02-98CH10886]
  3. U.S. Department of Energy, National Nuclear Security Administration, Office of Defense Nuclear Nonproliferation Research and Development (DNN RD)
  4. U.S. Department of Energy (DOE) [DE-SC0018974] Funding Source: U.S. Department of Energy (DOE)

向作者/读者索取更多资源

This paper investigates the performance of water-based liquid scintillators in detectors of different scales, comparing them with pure water Cherenkov detectors and pure scintillator detectors. The results support previous studies and propose a more detailed approach to detector design and research.
This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. Performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of T-1/2(0 nu beta beta) > 1.4 x 10(28) years at 90% C.L. for 10 years of data taking with a Te-loaded target.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据