Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

期刊

STEEL AND COMPOSITE STRUCTURES
卷 39, 期 5, 页码 529-542

出版社

TECHNO-PRESS
DOI: 10.12989/scs.2021.39.5.529

关键词

shear; stud connector; steel concrete composite; push test; fire exposure; elevated temperatures

向作者/读者索取更多资源

This study investigates the shear resistance and failure modes of headed stud shear connectors at fire exposure and post-fire exposure. Experimental results show a reduction in the ultimate shear capacity and stiffness of the connectors as temperature increases. Concrete with carbon nanotubes (CNTs) exhibited reduced spalling and cracking compared to ordinary concrete at temperatures above 400 degrees C.
Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600 degrees C. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600 degrees C. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400 degrees C. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据